Vehicle Loops and PD-132 Loop Detectors are used to detect the presence of a vehicle to open a gate, or as a safety device to prevent the gate from closing on a vehicle ...
PD-132 Loop detector in installed in barrier gate to detect verify if vehicle have finished passing through parking access control or parking ticketing lane. After car has completely passed through the boom gate, loop detector will give signal to barrier gate to start closing boom arm.
The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as “Loop installation guide”).
Excelsoo PD-132 Vehicle Loop Detector (frontside) |
Excelsoo PD-132 Vehicle Loop Detector |
Excelsoo PD-132 Vehicle Loop Detector |
Specification:
Description
Parameter
Supply voltage
230V AC, 115 AC, 24V DC/AC, 12V DC/AC
Voltage tolerance AC
+ 10% / – 15%
Voltage tolerance DC
± 15%
Power Consumption
4.5VA
Output relays
240V / 5A
Operating temperature
-20°C to +65°C
Storage temperature
-40°C to +85°C
Frequency range
20 kHz to 170 kHz
Reaction time
10ms
Signal holding time
Unlimited// Limited when loop is permanently covered 10 minutes
Sensitivity
Adjustable in 4 increments
Loop inductance
Total loop plus connection wiring
: 50µH to 1000µH. Ideal is 100µH
to 300µH
: 50µH to 1000µH. Ideal is 100µH
to 300µH
Loop connection wiring
Maximum length 20 meters, twisted at least 20 times per meter